Growth and Intake of Calves Fed Milk Replacer by Nipple Bottle or Computer Feeding System
J.D. QUIGLEY, lll, PAS, and B. J. BEARDEN
Institute of Agriculture, Department of Animal Science, University of Tennessee, Knoxville 37901-1071
________________________________________________
2-Introduction
3-Materials and Methods
4-Results and Discussion
5-Conclusions
6-Literature Cited
(Back to home page)
Commercial medicated milk replacer was fed at 460 gram/day in 4 liter of water divided into 2 feedings per day from nipple bottles or in 8 feedings per day from a computerized milk feeding system.
Calves were placed into one of two group pens containing 2 to 12 calves per pen at approximately 7 day of age for a 52-day trial.
A separate outdoor exercise area was connected to each pen.
Commercial calf starter (19.5% CD on a DM basis) was offered to each group of calves for ad libitum consumption.
Intake of milk replacer was lower (13 gram/day) when calves were fed by the computer feeder.
Reduced intake of milk replacer in the computer feeder was caused by calves occasionally losing their neck chains and by computer malfunctions during the experiment.
Body weight gain was increased by 120 gram/day (698 vs 578) when calves were fed by the computer.
Calves fed from the computer feeder had fewer incidences of inter-animal contact (n = 1) than calves fed from nipple bottles (n= 40) in the 1st hour after each feeding.
The computerized milk feeding system appears to be an effective and practical method feeding milk replacer to replacement calves.
Calf hutches are a popular method of housing calves that incorporate the concept of isolation to reduce the incidence of disease (5).
Calves have been housed in groups to reduce labor costs and for animal well-being concerns (13). Contact between calves is greater when calves are housed in groups, but Boe (1) and Boe and Havrevoll (2) reported little effect of housing on the prevalence of inter-animal sucking.
Negative behavior (inter-animal sucking) may be influenced more by the method of feeding; calves housed in groups and fed in one or two meals daily may be more likely to engage in inter-animal contact than those fed more frequently (10,13). Calves housed in groups have been fed milk replacer (MR) for ad libitum consumption or the amount of milk replacer consumed has been controlled by acidification (9, 11, 12).
Microprocessor-controlled milk feeding systems have been used with veal calves in Europe with success (1, 2, 3, 7, S, 10), although limited experience in the U.S. has been less positive (14). Microprocessors controlling most computerized milk replacer feeding systems can be programmed to control various management options, including concentration of reconstituted milk replacer, number of meals per day, reduction of amount of milk replacer fed to promote early weaning, and others.
The objective of this study was to measure the growth, intake, and behavior of herd replacement calves fed milk replacer twice daily from nipple bottles or eight times daily via a computer feeding system.
Forty Holstein bull (n = 20) and heifer calves born at the Middle Tennessee Experiment Station (Spring Hill, TN) were blocked by sex and assigned randomly at birth to a randomized complete block experiment.
Calves were fed colostrum (4 Lid) for 3 day, then were placed in individual metal stalls bedded with sawdust for an additional 4 to 5 day. Thereafter, calves were placed into one of two group pens (34 m2 per pen) containing 2 to 12 calves per pen. Pens were bedded with sawdust. A separate outdoor drylot exercise area (74 m2 per area) was connected to each pen. Calves were fed 460 gram of milk replacer in 4 liter of water equally divided into two feedings per day from nipple bottles (MRBottle) at a 10- to 12-hour interval or equally divided into eight feedings per day from a computerized milk feeding station (MRComputer); Automatic Nursing with Identification, Intersoft-Agri, Tullahoma, TN.
The microprocessor allowed each calf one meal of 500 mliter of reconstituted milk replacer (115 gram of milk replacer/liter) at 3-hour intervals. Upon entering the feeding station, the computer identified each calf by its magnetic neck chain. If feeding was allowed, milk replacer was mixed with warm tap water [approximately 120 F (48.9 C)] in a mixing chamber. After mechanical mixing, the reconstituted milk replacer was transferred to a feeding bowl and then was gravity- fed to a nipple in the feeding station.
Any milk replacer not consumed during a 3-hour period was credited to the next 3-hour period.
The computer cleaned mixing bowls and nipples six times daily by rinsing with hot tap water. No cleaning solution was used during cleaning cycles.
Plywood side waIls were added to the entrance of the feeding station to reduce competition among calves at the feeding station. Side walls were approximately 1.5 m long x 1 m high and effectively eliminated competition.
Commercial calf starter (Tennessee Farmers Cooperative, LaVergne, TN) was fed to each group of calves once daily in a feed bunk in each pen and was available for ad libitum consumption. Amount fed and refused was weighed daily. Commercial milk replacer (Tennessee Farmers Cooperative) was fed to both groups of calves.
The milk replacer was medicated with oxytetracycline (125 gram/ton) and neomycin (250 gram/ton) and contained protein from milk and modified soy flour.
Water was available at all times.
Calves were observed at each feeding for incidence of scours using the scale of 1 = normal fecal consistency to 4 = severe scours (6).
Calves were weighed at the start of the study (mean age = 7.6 day) and once weekly to approximately 56 day of age.
A video recorder with two cameras per pen was used to record the number of contacts by animals during the study. The camera recorded behavior once weekly beginning at approximately 0900 hour and continuing for 24 hour.
However, initial observation indicated that most (<90%) cross-nursing occurred within 1 hour of milk replacer feeding; therefore, data were reported for 1 hour postfeeding only at each feeding.
A contact was defined as one animal not previously in contact with another making oral contact with another calf.
Samples of milk replacer and calf starter were collected monthly, composited, and analyzed for DM, CP Ca, and P.
Intake of milk replacer, body weight, body weight gain and days scouring were pooled for the study and analyzed as a randomized complete block design by ANOVA.
Calves were blocked by date of birth and sex of calf. Preliminary analysis indicated that body weight at 7 d was not significant as a covariable in any analysis; therefore, no covariable was used. Significance was P<0.05 unless otherwise noted.
Calves were generally healthy throughout the trial. Two calves died (one per treatment) due to scours and one died (MRComputer) due to complications following a broken leg.
Mean days scouring was 2.6 day (Table 1); scours were generally not severe and were unrelated to treatment. Calves that were observed with scours were removed from the group pen and placed in an individual pen. Electrolytes were fed for 2 to 3 day and antibiotic therapy was initiated according to manufacturer's directions or until the animal's condition improved. Thereafter, the calf was returned to the group pen.
Intake of milk replacer was measured for each calf. Calves on treatment MRBottle were given a 2- liter nipple bottle at each feeding. Calves on treatment MRBottle were observed to minimize competition among animals and physically separating calves when competition occurred.
Calves on treatment MRComputer were trained upon entering the group pen. Training was uneventful; all calves learned to use the computer within 1 day, and most learned to use the computer within a few minutes.
Intake of milk replacer was lower (P<0.01) for calves on treatment MRComputer, although the difference between treatments was only 13 g/d (Table 1).
Reduced intake of milk replacer when calves were fed by the computer feeder was due to lost neck chains and a few computer malfunctions during the experiment.
Milk replacer used in the study was 91.5% DM and 22.8% CP (DM basis). Label guarantees for fat and crude fiber were 20 and 0.5% on an air-dry basis, respectively.
Body weight and body weight gain at the end of the study were greater for calves on MRComputer (trable 1). The increase in body weight gain was 120 g/d, an increase of 21% over calves on treatment MRBottle.
The increase in body weight with similar amounts of milk replacer feeding was unexpected. We found no other results in the literature suggesting such a marked increase in body weight gain with computerized feeding vs feeding from nipple bottles. The amount of milk replacer fed by the computer was determined by calibrating the weight of milk replacer powder provided per minute the screw feeder was engaged. This amount was used to calculate the length of time the screw feeder should be engaged to deliver the proper amount of milk replacer powden In addition, the milk replacer fed to calves on treatment MRBottle was weighed and calibrated to the cup provided by the manufacturer. Although the amount of milk replacer offered was calibrated weekly during the study, changes in milk replacer formulation (or size of the cup provided in each milk replacer bag) may have increased the amount of milk replacer mixed by the computer or decreased the amount of milk replacer mixed into nipple bottles.
Further studies are needed to confirm that body weight was in- creased when calves were fed similar amounts of milk replacer by the computerized feeder.
Intake of calf starter was not evaluated statistically, as animals were group-fed starter throughout the trial. Mean starter intakes during the study were 1067 and 1128 gram/day for calves on treatments MRComputer and MRBottle, respectively. Calf starter was 88.5% DM and 19.5% CP on a DM basis.
Closed circuit cameras were set up to monitor each pen of calves for 1 hour after each feeding. Calves were not monitored over a 24-hour period. Cameras were used 1 day/week throughout the study. Calves were identified by painting numbers on each animal's flank; however, it was not possible to identify each animal on treatment MRBottle immediately after feeding, as animals typically congregated in small groups for up to 60 mm after feeding. Therefore, number of contacts could not be evaluated statistically; inferences regarding the number of inter-animal contacts must be made with caution.
There was an average of one inter-animal contact per calf in the group of calves fed by computer in the first hour after calves were fed. Calves fed by computer had milk replacer available throughout the day; therefore, feeding calves on treatment MRBottle was not associated with intake of milk replacer by calves on treatment MRComputer. However, at each feeding, milk replacer was added to the computer hopper if necessary and pens were washed. Mean number of inter-animal contacts for calves on treatment MRBottle was 40 per calf in the 1st hour after feeding. Most contacts occurred in the first 10 mm after bottles were removed.
Video recordings clearly showed that calves fed by bottle attempted to continue nursing; most calves milled about in the feeding area and continued to nurse on other calves or on pen fixtures. This behavior declined with time after feeding until about 60 mm after feeding. video recordings also indicated little competition among calves on treatment MRComputer.
We observed few instances of calves forcing other calves out of the feeding station while drinking. However, the number of calves per group and social dominance of calves may influence the frequency of this behavior.
Most studies that have evaluated group housing systems have fed calves milk replacer for ad libitum consumption.
Generally, ad libitum consumpton leads to increased milk replacer intake, increased body weight gain and feed costs, and decreased intake of calf starter.
When a computerized system is used, however, calves may be housed in groups and limit- fed milk replacer with little competition among animals. Labor required to maintain the computer feeding system was minimal. Managenent of the computer feeder inducled daily evaluation of condition of the computer and feeding station, adding powdered milk replacer to the feed hopper once daily, down loading and printing the daily computer report, and ensuring that all calves maintained working neck chain. These management tasks were completed in a few minutes per day.
Conversely, feeding calves milk replacer by nipple bottle was more labor intensive and required 30 to 45 mm per feeding to mix milk replacer, feed calves, and thoroughly clean the bottles after feeding.
Feeding milk replacer to calves more frequently than twice daily generally has not resulted in improved body weight gain or efficiency of energy utilization (15, 16). However, Williams et al. (15) reported improved efficiency of fat digestibility in young calves (20 d of age) fed milk replacer six times daily compared to calves fed once daily. Williams et al. (15) fed milk replacer containing significant amounts of skim milk powder that coagulated in the abomasum and supplied energy nearly continuously from the gut in calves fed once daily.
However, it is not clear if a continuous supply of energy would be provided to calves fed once or twice daily when nonclotting milk replacer was fed. The milk replacer used in this study contained no skim milk or casein, so coagulation in the abomasum did not occur. Feeding frequency may be more important when calves are fed for ad libitum consumption than when limit-fed(2).
Maatje and Verhoeff (7) reported reduced rate of body weight gain in veal calves housed in groups and fed via computerized milk feeding system compared to those housed in individual crates and fed from buckets. Differences in body weight gain were attributed to lower milk replacer intake during the 161-day feeding period. Further, morbidity and mortality were greater when calves were housed in groups compared to individual housing. Maatje et al. (8) and Tomkins (14) also reported increased morbidity and mortality when veal calves were housed in groups and fed by computerized feeder.
In the current study, rate of morbidity and mortality were low and were unaffected by method of milk replacer feeding. Our calves were fed adequate amounts of high quality colostrum, isolated from mature animals, and proper hygiene was maintained throughout the study. Calves with diarrhea were separated from the group to minimize the spread of pathogens to other calves. Under these conditions, group housing with computerized feeding supported intake and rates of body weight gain similar or superior to calves housed in groups and fed conventionally.
Hammell et al. (4) concluded that calves have a requirement for sucking independent of milk intake. This need may not have been met when calves were fed on treatment MRBottle in the current study, as inter-animal sucking in the 1st hour after feeding was greater in this group. Calves fed by the computer feeder spent little time sucking, and apparently, continuouss availability of the nipple satisfied this need.
However, all group calves have the opportunity to engage in inter-animal contact, so use of a computerized milk replacer feeding system will not prevent all inter-animal contact.
Calves fed on treatment MRComputer and housed in groups had greater body weight gain than calves on treatment MRBottle.
Calves housed in groups had few occurrences of scours and excellent body weight gain.
Calves on treatment MRBottle engaged in more non-nutritional sucking than calves fed on treatment MRComputer.
The computerized milk replacer feeding system appears to be an acceptable alternative to individual feeding when animals are housed in groups.
TABLE 1 Change in body weight of calves housed in group and fed milk replacer two times per days from bottles or eight times per days from a computer feeder | ||||||
___________________________________ |
||||||
Item | Computer | SE | Bottle | SE | P | %change |
n | 18 | ... | 19 | ... | ... | ... |
Age at Start,day | 7.8 | 0.6 | 7.4 | 0.5 | NS | ... |
Age at end, day | 60.2 | 0.7 | 60.0 | 0.6 | NS | ... |
Days on trial | 52.3 | 0.8 | 52.5 | 0.8 | NS | ... |
Body weight at Start, kg | 39.8 | 0.9 | 40.9 | 0.9 | NS | ... |
Body weight at end,kg | 76.2 | 1.9 | 71.1 | 1.9 | 0.07 | +7 |
Body weight gain, g/d | 698 | 35 | 578 | 35 | 0.02 | +21 |
DMI,g/d Milk replacer | 435 | 4 | 448 | 4 | 0.01 | -3 |
DMI,g/d Calf Starter(a) | 1067 | ... | 1128 | ... | ... | -5 |
Inter-animal contact(b) | 1 | ... | 40 | ... | ... | ... |
Scours,d | 2.5 | 0.4 | 2.8 | 0.4 | NS | ... |
(a) Not analysed statistically as calves were fed in group (b) Number of oral contact made in the first hour after removing nipple bottles from the group fed by nipple bottles. Data were not analyzed statistically. |
2.Boe, K., and ~. Havrevoll. 1993. Cold housing and computer-controlled milk feeding for dairy calves: behaviour and performance. Anim. Prod. 57:183.
3.Ferrante, B., E. Canall, M. Verga, and C. Carenzi. 1991. Effects of computerized milk feeder on behaviour and welfare of calves. In New Trends In Veal Calf Production. J.H.M. Meti and C. M. Groenestein, (Ed.). Proc. of the Intl. Symp. of Veal Calf Production. p 76. MAP Pub. 52, Wageningen, Netherlands.
4. Hammell, ic L, J.H.M. Metz, and P Mekkekking. 1988. Sucking behaviour of dairy calves fed rank ad libitum by bucket or teat. Appi. Anim. Behav. Sd. 20:275.
5. Jorgensen. L J., N. A. Jorgensen. 0. J. Schingoethe. and M. 3. Owens. 1970. Indoor versus outdoor calf rearing at three weaning agetj. Dairy Sd. 53:813.
6. larson1 L L, F. G. Owen, 3. L. Albright, R. D. Appleman, R. C. Lamb, and L 0. Muller. 1977. Guidelines toward more uniformity in measuring and reporting calf experimental data. J. Dairy Sd. 60:989.
7. Maatte, K., and J. Verhoeff. 1991. Automated feeding of milk replacer and health control of group~housed veal calves. In New Trends in Veal Calf Production. J.H.M. Metz and C. M. Groenestein, (Ed.). Proc. Intl. Symp. on Veal Calf Prod. p fl. EMP PubI. 52, Wageningen, Netherlands.
8. Maatle, IC, J. Verhoeff, W.DJ. Kremer, A.LM. Cruljsen. and T.S.G.M. van den lngh. 1993. Automated feeding of milk replacer and health control of group-housed veal calves. Vet. Rec. 133:266.
9. Nocek, 3. &, and D. G. Braund. 1986. Pefformance, health, and postweaning growth on calves fed cold, acidified milk replacer ad libitum. 3. Dairy Sd. 69:1871.
10. Pirkelmann, H.. and F. Wendling. 1988. Miaoprocessor based feeding and controlling of calves. In Proc. of the 3rd Intl. Livestock Environ. Symp. p 248. Am. Soc. Agr. Eng.. St. Joseph, MI.
11. Richard, A. L., A.). Heinrichs1 and L 0. Muller. 1988. Feeding acidified milk replacer ad libitum to calves housed in groups versus individual pens.). Dairy Sci. 71:2203.
12. Richard, A. L, L D. Muller, and A.). Heinrichs. 1988. Ad libitum or twice daily feeding of acidified milk replacer to calves housed individually in warm or cold environments. 3. Dairy Sd. fl:2193.
13. Smits, A. C.. and 3. G. de Wilt. 1991. Group housing of veal calves. In New Trends in Veal Calf Production. Proc. Intl. Symp. on Veal Calf Prod. J.H.M. Met:t and C. M. Groenestein, (Ed.). EMP PubI. 52. p 61.Wageningen, Netherlands.
14. Tomklns, T. 1991. Loose-housing experience in North America. In New Trends in Veal Calf Production. J.H.M. Metz and C. M. Groenestein, (Ed.). Proc. Intl. Symp. on Veal Calf Prod. EMP PubI. 52. p 67. Wageningen, Netherlands.
15. Williams, PE.V, R. 3. Fallon, 3. M. Brockway, G.M. Innes, and A. C. Brewer. 1986. The effect of frequency of feeding milk replacer to pre-rurninant calves on respiratory quotient and the efficiency of food utilization. Anim. Prod. 43:367.
16. Woodford, S. T., H. 0. Whetstone, M. R. Murphy, and C. L. Davis. 1987. Abomasal pH, nutrient digestibility. and growth of Holstein bull calves fed acidified milk replacer.). Dairy Sd. 70:888.